> For the complete documentation index, see [llms.txt](https://docs.gantner.com/eloxx-365/HN3yXU2vWRZ8y5EuQtp8/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.gantner.com/eloxx-365/HN3yXU2vWRZ8y5EuQtp8/getting-started/terminologies.md).

# Terminologies

Understand key terms and concepts used in eLoxx 365.

This section explains the key terms and concepts used in eLoxx 365 documentation and locker management workflows.

| Terminology          | Description                                                                                                                                                                                                                                                                                                                                                                                                                                                 |
| -------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
| Data carrier         | <p>An identification medium containing a unique identifier (UID) used for authentication with GANTNER devices.</p><p></p><p>Common forms include cards, wristbands, or key tags.</p><p></p><p><strong>NOTE:</strong> The data carriers are used to identify the users of a facility at the GANTNER devices.</p>                                                                                                                                             |
| Lock / Locker lock   | <p>Electronic locking hardware used to secure lockers within the GANTNER locker system.</p><h4> </h4><p></p><h4>GAT NET.Lock 70x0</h4><p>Connected to a GAT NET.Controller S 7000 or 7020. Authentication occurs directly at the locker lock using RFID data carriers.</p><p></p><h4>GAT SMART.Lock 7001</h4><p>Connected to a GAT SMART.Controller S 7000 or 7020. Authentication occurs through a central terminal instead of directly at the locker.</p> |
| Locker users         | <p><strong>Locker users</strong> are the people who use lockers. They have a name (first name, last name) and can have more describing attributes. </p><p></p><p>Each user may possess multiple data carriers and are associated with one or more <strong>authorization groups</strong>, which define their access rights.</p>                                                                                                                              |
| Free locker          | <p>A locker in <strong>free locker</strong> <strong>mode</strong> can be locked and unlocked by any data carrier, under the following conditions:</p><ul><li>The data carrier has not already locked more than the set maximum number of lockers.</li><li>The data carrier is valid in the facility (valid UID or site key).</li></ul>                                                                                                                      |
| Personal locker      | A locker in **personal locker** **mode** can only be locked and unlocked by a data carrier assigned to it in the authorization list.                                                                                                                                                                                                                                                                                                                        |
| Dynamic locker       | <p>A locker in <strong>dynamic locker mode</strong> is a combination of a free locker and a personal locker.</p><p></p><p>Dynamic lockers can get occupied by locker users themselves or get assigned via the software and belong to the locker user as long as the locker assignment is valid.</p><p></p><p><strong>Use case:</strong> Temporary locker access for service personnel or visitors.</p>                                                      |
| Locker group         | Lockers are organized in a tree structure of **locker groups**. Each locker group can have locker groups as subgroups containing different lockers.                                                                                                                                                                                                                                                                                                         |
| Main controller      | Central control unit that manages communication with sub-controllers and coordinates the operations of connected electronic locks.                                                                                                                                                                                                                                                                                                                          |
| Sub-controller       | <p>The <strong>sub-controllers</strong> are controlled by a main controller or by a GAT SMART.Lock Axx 6350 or GT7 Central Locker terminal in the case of the GAT SMART.Lock 7001.</p><p></p><p>The electronic locks are connected to the sub-controllers. There is a sub-controller for every type of lock.</p>                                                                                                                                            |
| Authorization groups | **Authorization groups** manage how many lockers of which type and in which locker group can be occupied by a locker user. It can give access to various locker groups, including their subgroups.                                                                                                                                                                                                                                                          |
| Assignments          | **Assignments** can be used to assign a locker user to a specific locker.                                                                                                                                                                                                                                                                                                                                                                                   |
| Maintenance mode     | <p>A locker can be set to <strong>maintenance mode</strong> either manually or automatically (after a reservation has expired).</p><p></p><p>In this state, the lock is out of operation (LED flashes red/green) and cannot be used with a regular user data carrier. This function is intended for maintenance work, e.g., cleaning the locker after the reservation has expired.</p>                                                                      |
| Master card set      | <p>A <strong>master card set</strong> consists of a set of up to 10 master cards. Each device can get assigned to one master card set. </p><p></p><p>The cards listed in the master card set are stored on the device and can be used to open any locker connected to the device, even in emergency mode.</p>                                                                                                                                               |


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.gantner.com/eloxx-365/HN3yXU2vWRZ8y5EuQtp8/getting-started/terminologies.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.